Ultrasonic probe is a very important sensor which generate acoustic signals and also detect returned signals. The performance and imaging quality of ultrasonic scanner are highly affected by the characteristic and the structure(piezoelectric material, matching layer and acoustic lens) of probe.
Meditech has a probe line up for each application and can produce customer's designed products.
Moreover, the attestation of "ISO13485:2003" that is International Standard of the quality management system in medical devices acquired, and we will deliver secure, safe and high-quality product for medical devices.
Probe type | Feature | Application |
Central frequency |
Element |
Radius of curvature |
Main Product | |
---|---|---|---|---|---|---|---|
Linear type |
wide footprint and keep same field of view at deep part. |
|
2.5MHz | 15MHz |
64ch | 256ch |
- |
7.5MHz
Linear |
(Array Module) Sample Data |
(Probe) Sample Data |
|||||||
10MHz
Linear |
(Array Module) Sample Data |
||||||
(Probe) Sample Data |
|||||||
NEW
13MHz
Linear |
(Array Module) Sample Data |
||||||
NEW
15MHz
Linear |
(Array Module) Sample Data |
||||||
Convex(Curved) type |
wide footprint, field of view will be spreaded at deep part. |
|
2.5MHz | 7.5MHz |
64ch | 192ch |
5R | 80R |
3.5MHz
Convex (Curved) |
(Array Module) Sample Data |
(Probe) Sample Data |
|||||||
NEW
3.5MHz
Convex (Curved) (Single Crystal) |
(Array Module) Sample Data |
||||||
6MHz
Convex (Curved) |
(Array Module) Sample Data |
||||||
Phased(Sector) type |
small footprint, field of view will be spreaded widely at deep part. |
|
2MHz | 7.5MHz |
32ch | 128ch |
- |
2.5MHz
Phased (Sector) |
(Array Module) Sample Data |
(Probe) Sample Data |
|||||||
Single type |
A) The measurement of distance. B) B mode scanning by mechanical rotation. |
|
2MHz | 22MHz |
- | - |
7.5MHz
Single type |
(Array Module)Sample Data |
20MHz
Single type |
(Array Module)Sample Data |
Probe type | Feature | Application |
Central frequency |
Element | Radius |
Main Product (Probe) |
|
---|---|---|---|---|---|---|---|
Linear type |
Real time 3D probe with the linear scanning type. |
|
7.5MHz | 11MHz |
128ch | 192ch |
- |
Mechanical
Scanning 3D 8MHz Linear |
Sample Data |
Convex(Curved) type |
Real time 3D probe with the wide field of view. |
|
3.5MHz | 6.5MHz |
128ch | 192ch |
40R |
Mechanical
Scanning 3D 4.5MHz Convex(Curved) |
Sample Data |
TV type |
Real time 3D probe with the wide field of view. |
|
6MHz |
128ch | 192ch |
10R |
Mechanical
Scanning 3D 6MHz TV |
High frequency probe can get the fine imaging with good resolution.
However the imaging of deep part will be smudgy due to wave length is short.
Meanwhile the imaging resolution of low frequency probe is low but ultrasonic wave can reach deep part. The scanning depth and resolution are mainly determined by the frequency of probe.
Frequency | Resolution | Penetration | Possible scanning depth |
---|---|---|---|
High | Fine | Weak | Shallow |
Low | Rough | Strong | Deep |
Specifications described in this site are subject to change without notice for improvement.
Meditech Equipment Co.,Ltd is part of Meditech Group. Product(s) described may not be licensed or available for sale in all countries. Sonotech, Sonovet, iSonic, FOs2pro, Dolphi, Defi, HeartRec,miniScan,Cardios,SpirOx,iBreath, Meditech and all corresponding design marks are trademarks of Meditech. The symbol indicates the trademark is registered. Patent and Trademark Office and certain other countries. All other names and marks mentioned are the trade names, trademarks or service marks of their respective owners. Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.