ET-7 External Side Stream ETCO2 module Advanced low flow side stream module;Easier to be operated on monitor and anesthesia machines;
The end tidal CO2 monitor that we have developed at Meditech is known as the MD-ET7. This highly advanced piece of equipment is designed to be easy to use and deliver consistently accurate vital signs information every single time it’s used. Whether you need to monitor the exhaled breath of a patient under general anesthesia, or you are interested in having an end tidal CO2 monitor on hand to identify ventilation-related problems before they become more serious, we are able to assist.
The EnTide is a field upgradable module that is designed to be used alongside one of the patient monitors that we offer at Meditech, providing you with rapid capnograph results. This equipment features a low flow, sidestream design that makes it practical for use with both intubated and non-intubated patients. Additionally, the EnTide:
Real time CO2 Concentration Respiration Rate End-tidal CO2 and Inspired CO2.
Features reliable filter cells that help prevent contamination, ensuring the data is as accurate as possible
Is extremely user friendly and designed to be used with minimal training
Is highly portable and can be transported along with the medical monitor with the patient as necessary
Can monitor both EtCO2 as well as EtCO2 along with automatic identification of various anesthetic agents
Has simple connection sample lines, which makes the system one of the lowest cost per patient systems currently available
If you need to monitor the exhaled breath of patients under your care, the Infinium EnTide is an excellent investment.
This system is easy to use, delivers reliable data, and can help you improve your quality of care
This system is easy to use, delivers reliable data, and can help you improve your quality of care
Sensor type | Side stream |
Technical principle | Non-dispersive infrared gas analysis |
Storage condition | -40o to 70oC, <90% RH, non-condensing |
Working condition | 5℃—50℃°, 10 to 90% RH, non-condensing |
Circumstance pressure | 86—106kPa |
Power demand | 5 V±5% (max ripple 200 mVp-p) |
Power consumption | Usual typical value 120mA during deviation and calibration, typical value 280mA |
CO2 measurement range | 0-19.7%(0-150mmHg,or 0-20kPa) |
CO2 resolution | 0.1mmHg |
CO2 measurement accuracy |
0 – 40 mmHg ±2 mm Hg 41 – 70 mmHg ±5% of reading 71 – 100 mmHg ±8% of reading 101 – 150 mmHg ±10% of reading Above 80 BPM ±12% of reading |
Respiration rate | 3~150 BPM |
Respiration rate accuracy | 1% ±1BPM |
Anesthetic gas compensation | N2O,O2,Agent(HOST supplied) |
Output Data | EtCO2,Respiratory Rate, Real-time CO2, Fico2, aspiratory time, expiratory time, barometric pressure |
Warm-up time | To reach designed deviation 97% within 45s, to reach designed deviation within 2 min。 |
Rise times( t10-90 %) | About 100ms when the flow is 50 ml/min adult water trap with sampling line 1.5m |
Delay time | <3sec when flow is 50 ml/min adult water trap with sampling line 1.5m |
Flow control | 50±10ml/min |
Automatic deviation calibration | To proceed automatically in 5-8 seconds according to time and temperature |
Exhaust port | yes |
Zeroing port | yes |
Water trap test | Pump works when water trap is installed and pump does not work when water trap is unplugged. |
Gas path obstruction, gas leakage and abnormal pump | To judge according to pressure and flow. |
Water Resistance | IPX4-Splash-proof (when the water trap is plugged in) |
Product Features
Features reliable filter cells that help prevent contamination, ensuring the data is as accurate as possible
Is extremely user friendly and designed to be used with minimal training
Is highly portable and can be transported along with the medical monitor with the patient as necessary
Can monitor both EtCO2 as well as EtCO2 along with automatic identification of various anesthetic agents
Has simple connection sample lines, which makes the system one of the lowest cost per patient systems currently available
If you need to monitor the exhaled breath of patients under your care, the Infinium EnTide is an excellent investment.
This system is easy to use, delivers reliable data, and can help you improve your quality of care
This system is easy to use, delivers reliable data, and can help you improve your quality of care
Product Specifications
Sensor type | Side stream |
Technical principle | Non-dispersive infrared gas analysis |
Storage condition | -40o to 70oC, <90% RH, non-condensing |
Working condition | 5℃—50℃°, 10 to 90% RH, non-condensing |
Circumstance pressure | 86—106kPa |
Power demand | 5 V±5% (max ripple 200 mVp-p) |
Power consumption | Usual typical value 120mA during deviation and calibration, typical value 280mA |
CO2 measurement range | 0-19.7%(0-150mmHg,or 0-20kPa) |
CO2 resolution | 0.1mmHg |
CO2 measurement accuracy |
0 – 40 mmHg ±2 mm Hg 41 – 70 mmHg ±5% of reading 71 – 100 mmHg ±8% of reading 101 – 150 mmHg ±10% of reading Above 80 BPM ±12% of reading |
Respiration rate | 3~150 BPM |
Respiration rate accuracy | 1% ±1BPM |
Anesthetic gas compensation | N2O,O2,Agent(HOST supplied) |
Output Data | EtCO2,Respiratory Rate, Real-time CO2, Fico2, aspiratory time, expiratory time, barometric pressure |
Warm-up time | To reach designed deviation 97% within 45s, to reach designed deviation within 2 min。 |
Rise times( t10-90 %) | About 100ms when the flow is 50 ml/min adult water trap with sampling line 1.5m |
Delay time | <3sec when flow is 50 ml/min adult water trap with sampling line 1.5m |
Flow control | 50±10ml/min |
Automatic deviation calibration | To proceed automatically in 5-8 seconds according to time and temperature |
Exhaust port | yes |
Zeroing port | yes |
Water trap test | Pump works when water trap is installed and pump does not work when water trap is unplugged. |
Gas path obstruction, gas leakage and abnormal pump | To judge according to pressure and flow. |
Water Resistance | IPX4-Splash-proof (when the water trap is plugged in) |
Related Accessories
Related items
ET-7 External Side Stream ETCO2
ET-7 External Side Stream ETCO2 module Advanced low flow side stream module;Easier to be operated on monitor and anesthesia machines;Real time CO2 Concentration Respiration Rate End-tidal CO2 and Inspired CO2.