12 channel simultaneous ECG (patient cable: 10 wires, independent (easy to remove))
Automatic measurement and analysis (PC Interface: USB port)
Pacemaker analysis, multi form printing
VCG and VLP (option), Isolated USB
Sampling rate: A/D: 24K SPS/channel, recording: 1000 SPS/channel
Quantization accuracy: A/D: 24 bit, recording: 16 bit
Resolution: 0.4uV
Frequency response: 0.05-250Hz (±3dB)
Common mode rejection: > 90dB
Input impedance: > 10MΩ
Time constant: 23.25ec
Maximum electrode potential: ±300mV
DCD ynamic range: ±12mV
Isolation voltage: 4000V
Patented multi channel synchronous A/D
Defibrillation protection: Built in box
Automatic measurement and analysis (PC Interface: USB port)
Pacemaker analysis, multi form printing
VCG and VLP (option), Isolated USB
Sampling rate: A/D: 24K SPS/channel, recording: 1000 SPS/channel
Quantization accuracy: A/D: 24 bit, recording: 16 bit
Resolution: 0.4uV
Frequency response: 0.05-250Hz (±3dB)
Common mode rejection: > 90dB
Input impedance: > 10MΩ
Time constant: 23.25ec
Maximum electrode potential: ±300mV
DCD ynamic range: ±12mV
Isolation voltage: 4000V
Patented multi channel synchronous A/D
Defibrillation protection: Built in box
Sampling Rate: A/D: 24K SPS/Channel
Recording: 1000 SPS/Channel
Recording: 1000 SPS/Channel
Quantization Precision: A/D: 24 Bits
Recording: 16 Bits
Recording: 16 Bits
Resolution: 0.4μV
Frequency Response: 0.05-250Hz (±3dB)
Common Mode Rejection: >90dB
Input Impedance: >10MΩ
Time Constant: ≥3.2Sec.
Maximum Electrode Potential: ±300mV DC
Dynamic Range: ±12mV
Isolate Voltage: 4000V
Patent Multi-Channel Synchronous A/D
Defibrillation Protect: Built-in box
Patient Current Leek: <10μA
Standard:
Chest Electrode ............ 6Pcs
Clamp Electrode .............. 4Pcs
Cleaning Cloth ................... 1Pcs
Options:
PC(Computer) accessories
Trolley
Printer accessories
Chest Electrode ............ 6Pcs
Clamp Electrode .............. 4Pcs
Cleaning Cloth ................... 1Pcs
Options:
PC(Computer) accessories
Trolley
Printer accessories
Product Features
12 channel simultaneous ECG (patient cable: 10 wires, independent (easy to remove))
Automatic measurement and analysis (PC Interface: USB port)
Pacemaker analysis, multi form printing
VCG and VLP (option), Isolated USB
Sampling rate: A/D: 24K SPS/channel, recording: 1000 SPS/channel
Quantization accuracy: A/D: 24 bit, recording: 16 bit
Resolution: 0.4uV
Frequency response: 0.05-250Hz (±3dB)
Common mode rejection: > 90dB
Input impedance: > 10MΩ
Time constant: 23.25ec
Maximum electrode potential: ±300mV
DCD ynamic range: ±12mV
Isolation voltage: 4000V
Patented multi channel synchronous A/D
Defibrillation protection: Built in box
Automatic measurement and analysis (PC Interface: USB port)
Pacemaker analysis, multi form printing
VCG and VLP (option), Isolated USB
Sampling rate: A/D: 24K SPS/channel, recording: 1000 SPS/channel
Quantization accuracy: A/D: 24 bit, recording: 16 bit
Resolution: 0.4uV
Frequency response: 0.05-250Hz (±3dB)
Common mode rejection: > 90dB
Input impedance: > 10MΩ
Time constant: 23.25ec
Maximum electrode potential: ±300mV
DCD ynamic range: ±12mV
Isolation voltage: 4000V
Patented multi channel synchronous A/D
Defibrillation protection: Built in box