Defi®5s eXtra advanced Automated External Defibrillator "AED"
with screen that guides the user step-by-step through the rescue procedure and display of the heart rhythm before shock delivery

Read More with screen that guides the user step-by-step through the rescue procedure and display of the heart rhythm before shock delivery

The screen guides the user step by step through the rescue process
Display of the heart rhythm before the shock is delivered
Color Screen for CPR process and display ECG rhythm
2 languages to choose (by the end user)
5 volume levels (by the end user)
Button for adult/child mode
PC software for data transmission (Option)
Daily, weekly and monthly self-test
Use of AED in pocket (does not need to be opened)
Extra pocket in the bag for first aid products
IPX55 water and dust resistant
Selectable energy for patients of different ages
30. 30. 50 Joule
50. 50. 75 Joule
120. 120. 150 Joule
150. 150. 200 Joule
Comprehensive voice and image prompts for the operator
Manually switchable language
Biphasic energy delivery
Interlock protection to prevent accidental defibrillation
ECG signals and events can be transferred to computer
Comes with carrying case, battery and pad,
It has a long life disposable LiMnO2 type battery (battery life at least 5 years)
-
AED storage software (standard configration)
Used to support the upper monitoring system of the DEFI® automated external defibrillator
1 Data communication
DefiSoft AED software supports receiving data sent via infrared,
Reading and setting ECG waves, setting Defi®5s eXtra language, reading, analyzing and saving data can also be done with Meditech Defi®5s eXtra Memory software.
2 Case management
DefiSoft converts the selected data file into a case record and stores cases in the database ACCESS.
Case management supports importing and deleting data and can respond to the ECG waveform of the file by selecting cases.
3 Memory playback
The interfaces display status information recorded during the operation of the
Defi®5s eXtra recorded status information, including type, event time, description, and waves.
Event type includes: On event, Self test event, Analysis event, Charge event, Discharge event, CPR start event, CPR stop event. Event time displayed indicates when the event occurred. Description displays the parameter information. "OHM" displays the detected impedance of the patient. The parameter "Power" indicates the voltage of the completed charge; "Shock required" indicates that a shock is recommended after the analysis; "No shock required" indicates that no shock is recommended after the analysis.
4 ECG
Waveform gain can be set to 5mm/mv, 10mm/mv, 20mm/mv; waveform speed can be set to 12.5mm/s, 25mm/s, 50mm/s:
5 Print
Displays a preview of the selected page and prints basic information
Technical data
Type: | Automatic External Defibrillator AED |
Self-test: | Daily, Weekly, Monthly |
Mode: | Adult, Child |
Waveform: | Biphasic truncated exponential |
Energy: | 200 Joule max. |
Energy Sequence: |
Child Mode: 30, 30, 50 Joule 50, 50, 75 Joule Adult Mode: 120, 120, 150 Joule 150, 150, 200 Joule |
Charge time: (New, at 25℃) |
Less than 6 sec. to 150J Less than 8 sec. to 200J |
Voice Prompt: | Extensive voice prompt |
Visual Indicators: | LED prompts |
Control: | Two buttons: ON/OFF, Shock |
ECG storage: | 1800 events. |
Data transmission | Infrared |
Battery |
|
Power: | 12V, 3000mAh |
Type: | Non-rechargeable |
Li-MnO2 Cell | |
Environmental | |
Operating Temperature |
0℃ to 40℃ |
Operating Humidity |
Relative humidity between 30% and 95% (non-condensing) |
Storage Temperature (without battery) |
-20℃ to 55℃ |
Storage Humidity (without battery) |
Up to 93% (non-condensing) |
Physical |
|
Dimensions | |
Weight (with battery): |
1.9Kg (4.2 Pounds) |
Standard:
AED Pad .................... 1Pcs
Battery ...........................1Pcs
AED carry Case ...... ...... 1Pcs
Cleaning Cloth ................1Pcs
Options:
AED Cabinet
AED Sign
AED bracket
IrDA USB Adapter for ECG Data transfer
Bluetooth Adaptor for ECG data transfer
Product Features
-
AED storage software (standard configration)
Used to support the upper monitoring system of the DEFI® automated external defibrillator
1 Data communication
DefiSoft AED software supports receiving data sent via infrared,
Reading and setting ECG waves, setting Defi®5s eXtra language, reading, analyzing and saving data can also be done with Meditech Defi®5s eXtra Memory software.
2 Case management
DefiSoft converts the selected data file into a case record and stores cases in the database ACCESS.
Case management supports importing and deleting data and can respond to the ECG waveform of the file by selecting cases.
3 Memory playback
The interfaces display status information recorded during the operation of the
Defi®5s eXtra recorded status information, including type, event time, description, and waves.
Event type includes: On event, Self test event, Analysis event, Charge event, Discharge event, CPR start event, CPR stop event. Event time displayed indicates when the event occurred. Description displays the parameter information. "OHM" displays the detected impedance of the patient. The parameter "Power" indicates the voltage of the completed charge; "Shock required" indicates that a shock is recommended after the analysis; "No shock required" indicates that no shock is recommended after the analysis.
4 ECG
Waveform gain can be set to 5mm/mv, 10mm/mv, 20mm/mv; waveform speed can be set to 12.5mm/s, 25mm/s, 50mm/s:
5 Print
Displays a preview of the selected page and prints basic information
Technical data
The screen guides the user step by step through the rescue process
Display of the heart rhythm before the shock is delivered
Color Screen for CPR process and display ECG rhythm
2 languages to choose (by the end user)
5 volume levels (by the end user)
Button for adult/child mode
PC software for data transmission (Option)
Daily, weekly and monthly self-test
Use of AED in pocket (does not need to be opened)
Extra pocket in the bag for first aid products
IPX55 water and dust resistant
Selectable energy for patients of different ages
30. 30. 50 Joule
50. 50. 75 Joule
120. 120. 150 Joule
150. 150. 200 Joule
Comprehensive voice and image prompts for the operator
Manually switchable language
Biphasic energy delivery
Interlock protection to prevent accidental defibrillation
ECG signals and events can be transferred to computer
Comes with carrying case, battery and pad,
It has a long life disposable LiMnO2 type battery (battery life at least 5 years)