• patient monitor,Meditech Patient monitor,ecg patient monitor
  • patient monitor,Meditech Patient monitor,ecg patient monitor
  • patient monitor,Meditech Patient monitor,ecg patient monitor
MD9000S patient monitor, monitoring ECG, SPO2, NIBP, RESP.2- TEMP. PR as standard parameters, and 2-IBP, ETC02 and thermal printer as options,
MD9000s patient monitor has a 12.1"color TFT screen.

Product Features

    Patient monitor with High-resolution 12.1-inch TFT color display
    Lightweight, compact and portable
    ECG waveforms of the 7-channel display
    Maximum 8-channel waveform synchronous display 72-hour trends in graphical and tabular form for all parameters 480 alarm events retrievable for all parameters
    Standard configuration: 3/5 leads ECG, NIBP, SpO2, RESP, 2-Temp, PR, printer
    NIBP measurement mode: manual/AUTO/STAT, memory for 4800 NIBP group data
    Suitable for adult, pediatric and neonatal patients
    Data and waveforms can be color-customized
    Arrhythmia analysis and S-T segment analysis
    Standard interface, oxygen diagram, trend diagram, interface with large font and comfortable bed for observation
    Heart rate variability (HRV) analysis function
    Drug concentration calculation and titration table functions
    Connection to central monitoring system via 3G, Wi-Fi or wired mode
    AC/DC, removable rechargeable lithium battery for continuous monitoring
    Anti-high frequency surgical device, defibrillation safe (special cables are required)
    Multilingual
    Capacity 150 minutes continuous operation
    
    Options:
    IBP, EtCO2 and thermal printer

Product Specifications

    ECG
    Lead mode 5 leads ( R, L, F, N, C or RA, LA, LL, RL, V)
    Lead selection I, II, III, avR, avL, avF, V,
    Waveform 2 ch
    Derivative mode 3 derivatives ( R, L, F or RA, LA, LL)
    Line selection I , II, III,
    Waveform 1 ch
    Gain ´2.5 mm/mV, ´5.0 mm/mV, ´10 mm/mV, ´20 mm/mV
    HR and alarm
    
    Range
    Adult 30 ~ 300 bpm
    Neo/Ped 30 ~ 350 bpm
    Accuracy ±1% or ±1bpm, which is very good
    Resolution 1 bpm
    Sensitivity > 200 uV P-P
    Differential input impedance > 5 MΩ
    CMRR
    Monitoring > 105 dB
    Operation > 105 dB
    Diagnostics > 85 dB
    Electrode offset potential ±300mV
    Leakage current < 10 uA
    Baseline recovery < 10 s after defi.
    ECG signal range ±8 mV (Vp-p)
    
    Bandwidth
    Surgery 1 ~ 15 Hz
    Monitoring 0.5 ~ 35 Hz
    Diagnostics 0.05 ~ 100 Hz
    Calibration signal 1 mV (Vp-p), ±5% accuracy
    
    ST segment monitoring range
    Measurement and alarm -2.0 ~ +2.0 mV
    
    ARR detection
    Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT > 2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
    Alarm available
    Verification available
    High T-wave suppression 1.2 mV
    Heart rate averaging from the average of the last 6 R-R intervals, without maximum and minimum
    Display update rate 1s
    Heart rate measurement accuracy and response to irregular rhythms:
    Bigeminy ventricular 80bpm
    Bigeminy ventricular alternatively lente 57 or 63bpm
    Bigeminy ventricular alternatively fast 122 or 123bpm
    Systole bidirectional 95 beats per minute
    Response time to heart rate monitor for a change in heart rate of 80 to 120 bpm
    Average 3.7s
    Range 3.2s ~ 4.1s 80 to 40 bpm
    Average 4.7s
    
    NIBP
    Method Oscillometric
    Mode Manual, Auto, STAT
    Measuring interval in AUTO mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120,240,480,960min
    Measuring time in STAT mode 5 min
    Pulse rate range 40 ~ 240 bpm
    Alarm type SYS, DIA, MEAN
    
    Measuring and alarm range
    Adult mode
    SYS 40 ~ 270 mmHg
    DIA 10 ~ 215 mmHg
    MEDIUM 20 ~ 235 mmHg
    Pediatric mode
    SYS 40 ~ 200 mmHg
    DIA 10 ~ 150 mmHg
    MEDIUM 20 ~ 165 mmHg
    Neonatal mode
    SYS 40 ~ 135 mmHg
    DIA 10 ~ 100 mmHg
    MEDIUM 20 ~ 110 mmHg
    
    Resolution
    Pressure 1mmHg
    Accuracy
    Pressure
    Maximum mean error ±5mmHg
    Maximum standard deviation ±8mmHg
    
    Protection against overpressure
    Adult mode 297±3 mmHg
    Pediatric mode 240±3 mmHg
    Neonatal mode 147±3 mmHg
    
    TEMPERATURE
    Channel 2
    Measuring and alarm range 0 ~ 50 °C
    Resolution 0,1°C
    Accuracy ±0,1°C
    Update interval approx. 1 sec.
    Average time constant < 10 sec.
    
    IBP (optional)
    Channel 2
    Designation ART, PA, CVP, RAP, LAP, ICP, P1, P2
    Measuring and alarm range
     ART 0~300mmHg
     PA -6~120mmHg
     CVP/RAP/ LAP /ICP -10~40mmHg
     P1~P2 -10~300mmHg
    Pressure sensor
     Sensitivity 5 uV/V/mmHg
     Impedance 300-3000Ω
    Resolution 1mmHg
    Accuracy ±2% or 1mmHg, which is very good
    Update interval about 1 second
    
    Display
    Device
    12.1 in. Color TFT, manufactured by Sharp Japan
    
    Messages 7 waveforms Maximum 1 alarm LED ( Yellow/Red)
    Screenshot 1 Power LED (Green)
    1 Battery charge LED ( Yellow)
    3 Sound mode corresponding to the alarm mode
    
    Signal interface
    ECG output BNC
    Amplitude 1 V/mV
    Accuracy < 5 %
    Impedance 50 Ω
    Signal delay < 20 mS
    Recall

Related Products

Promoted Products

Meditech Equipment Co.,Ltd is part of Meditech Group. Product(s) described may not be licensed or available for sale in all countries. Sonotech, Sonovet, iSonic, FOs2pro, Dolphi, Defi, HeartRec,miniScan,Cardios,SpirOx,iBreath, Meditech and all corresponding design marks are trademarks of Meditech. The symbol indicates the trademark is registered. Patent and Trademark Office and certain other countries. All other names and marks mentioned are the trade names, trademarks or service marks of their respective owners. Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.

Legal notice Terms and conditions Cookie policy Privacy Policy Professional organisations Careers

To Top