• patient monitor 15inch touch screen
  • patient monitor 15inch touch screen
  • patient monitor 15inch touch screen
MD9015T
​15-inch touchscreen patient monitor 192-hour trend graph, 1000 blood pressure groups, ST segment measurements, arrhythmia analysis and other features,
Supports up to 32 TCP/IP network connections, consisting of a central information system.
Comes with remote control


Masimo spo2 module (Option)

Product Features

    Color display with a resolution of 15 inches
    Touchscreen operation more efficient and convenient
    Operation via remote control
    Fulfill the alarm system eye-catching sub column independently with the YY0709
    Waming lights can be three sound and light alarm immediately
    Pacing analysis can be used simultaneously with pacemakers defibrillators 192 hours trend graph waveform freeze 1000 group of blood pressure list
    ST segment measurements arrhythmia analysis
    Various types of multi-line ECG capital letter respiration oxygen content short trend display interface
    Multi-level alarm function to adjust the pulse volume; parameter display colors can be customized according to user preference
    User information management functions for entering patient information and identity management
    External replaceable lithium battery for 120 minutes of continuous operation
    External recorder can print out the recorded waveform data and other information in real time
    Drug concentration setting and recording for titration calculations to support event functions
    Up to 32 TCP/IP network connections, consisting of a central information system
    Wireless network
    
    Options:
    Blood pressure, EtCO2 and thermal printer

    MD9015T Support:
    DC power supply and adaptation to a wide range of environmental conditions
    External recorder can print the recorded waveform data and other information in real time
    External EtCO2 interface can be connected to the CO2 module to meet clinical requirements
    Adjustment and recording of drug concentration in titration calculations to support event functions
    Up to 32 TCP/IP network connections to form a centralised information system
    Wireless networking
    
    Options
    Invasive blood pressure (IBP)
    Carbon dioxide (CO2) module
    Masimo SpO2 Module
    Thermal printer
    Built-in Wifi

Product Specifications

    Electrocardiogram (ECG)
    Input mode Five-lead ECG input / three-lead ECG input
    Lead selection I, II, III, aVR, aVL, aVF, V-
    Gain selection AUTO,0.25X,0.5X,1X,2X,4X
    Operating mode Diagnostic mode, monitoring mode, operation mode
    Calibration signal 1mV ±5%
    Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife. Anti-defibrillation protection.
    Pacemaker at the same time use Support
    Electrode off instructions Each electrode (RL excluded)
    Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s
    Common mode rejection ratio ≥90dB
    Input impedance ≥5.0MΩ
     
    Heartrate (HR)                          

    Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpm
    Resolution 1 bpm
    Accuracy < ±5bpm
    Heart rate sensitivity ≥0.20mVp-p
    Alarm range 15 to 350 bpm, upper and lower limits
    Alarm indication Audible and visual alarm, display the data and parameters flashing display alarm 
    message text prompts, there are three levels of alarm
     
    Pulse Oximetry
    SPO2 Range:                          1% to 99%
    Resolution:                              1%
    Accuracy:                                70% to 99% range: ±2%;
    1% to 69% range:                    ±5%;
    Method:                                  Dual wavelength LED 

    ST-segment

    ST-segment measurement range -2.0~+2.0mV
    ST-segment measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%,
    Whichever is greater; Other range: undefined
    Resolution 0.01mV
    ST-segment update cycle 10s
    ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable
     
    Arrhythmia analysis

    Arrhythmia types 13 kinds of (scalable)
     
    Respiration Rate
    Rate:                                  2 to 120 bpm (CO2)
    Resolution:                        1 breath/min
     
    NIBP (Non-invasive Blood Pressure)
    Technique:                        Oscillometric during inflation
    Range:                               Adult/Pediatric: 40 to 240 mmHg
    Neonate:                           10 to 150 mmHg
    Measurement Cycle:         < 40 sec. typical
    Automatic Measurement
    Cycles (Selectable):          2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
    STAT Mode:                      5 minutes of continuous readings
    Max. Allowable Cuff
    Pressure: Adult:                300mmHg
    Pediatric:                          240 mmHg;
    Neonate:                          150 mmHg
    Resolution:                       1 mmHg
    Transducer Accuracy:       ±2 mmHg or ±2% of reading,
    Heart (Pulse) Rate
    Range:                              30 to 250 bpm
    Accuracy:                        ±2 bpm or ±3%, whichever is greater


    EtCO2 technological index


    Interface form External interface
    Range of
    measurement
    0~10 kPa or (0~75) mmHg
    precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、
    (5.5kPa~10.0kPa)the error is ±0.7kPa
    Alarm upper limit 2.1~13.2 kPa
    Alarm lower limit 0~6.5 kPa
    time 12s
    EtCO2 exist
    Unit kPa / mmHg / %
    Compatibility  
    external main stream and side stream are compatible

    IBP technological index
     
    Measured channel Single way and double way are optional
    Range of
    measurement
    SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg)
    MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg)
    DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg)
    Mean error ≤±0.4kPa (±3mmHg)
    Range of alarm SYS:  upper limit   0.3kPa~53.3kPa(2mmHg~400mmHg)
    Lower limit   0kPa~53.1kPa(0mmHg~398mmHg)
    MEAN:  upper limit    0.3kPa~53.3kPa (2mmHg~400mmHg)
    Lower limit   0kPa~53.1kPa (0mmHg~398mmHg)
    DIA:    upper limit    0.3kPa~53.3kPa ( 2mmHg~400mmHg)
                 Lower limit   0kPa~53.1kPa ( 0mmHg~398mmHg)
    Measured unit mmHg/kPa
    Specification of
    sensor
    DPT-248(space)
    Consumables mode SCW-UTAH-01
       
       
       
       
       

Related Products

Promoted Products

Meditech Equipment Co.,Ltd is part of Meditech Group. Product(s) described may not be licensed or available for sale in all countries. Sonotech, Sonovet, iSonic, FOs2pro, Dolphi, Defi, HeartRec,miniScan,Cardios,SpirOx,iBreath, Meditech and all corresponding design marks are trademarks of Meditech. The symbol indicates the trademark is registered. Patent and Trademark Office and certain other countries. All other names and marks mentioned are the trade names, trademarks or service marks of their respective owners. Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.